Skip to Main Content
  • Linde Worldwide
  • The Linde Group
  • Glossary
  • Contact us
  • Specialty Gases & Specialty Equipment

  • Home
  • Specialty gases
      • Gas mixtures
      • Instrumentation gas table
      • Euro 6 gases & gas mixtures
      • Industrial laser gases
      • Rare gases
      • Zero gases
      • Specialty gases cylinder outlets
      • Portable cylinders
      • Supply modes
      • CAS number listing
      • Material compatibility
      • Physical data
  • Specialty equipment
      • REDLINE® cylinder regulators
        • C 200
        • C 300
        • GENIE®
        • Inlet / outlet connections
      • REDLINE® installation equipment
        • Manual panels
        • Semi-automatic panels
        • Outlets / POUs
        • Accessories
      • BASELINE® cylinder regulators
        • C 106/1
        • C 106/2
        • C 106X/1, R 104/1, V 106P/1
        • Inlet / outlet connections
      • BASELINE® installation equipment
        • Manual panels
        • Semi-automatic panels
        • Outlets / POUs
        • Accessories
  • Analytical methods
      • Gas chromatography
        • Electron capture detector (ECD)
        • Flame ionisation detector (FID)
        • Flame photometric detector (FPD)
        • Mass spectrometry (MS)
        • Thermal conductivity detector (TCD)
      • Liquid chromatography
        • High performance liquid chromatography (HPLC)
        • Mass spectrometry (LC-MS)
      • Infrared spectroscopy
        • Fourier transform infrared (FT - IR) spectroscopy
        • Non dispersive infrared (ND-IR) spectroscopy
      • Other spectroscopy
        • Absorption spectroscopy
        • Chemiluminesence spectroscopy
        • Emission spectroscopy
        • Fluoresence spectroscopy
        • X-ray fluorescence spectroscopy
        • Gamma-ray spectroscopy
        • Near infrared spectroscopy
      • Other methods
        • Particle/nuclear counters
        • Paramagnetic method
        • Supercritical fluid
        • Thermal methods
        • Portable gas detectors
      • Inductively coupled plasma
      • Mass spectrometry
      • Nuclear magnetic resonance
  • Quality & safety
      • Quality
        • Accreditation
        • Certification
        • Cylinder filling
        • Cylinder pre-treatment
        • Dual port valves
        • Metrology
        • Mixture tolerances
        • Purity
        • Traceability
      • Safety
        • Corporate responsibility
        • Dangerous substances
        • Product legislation
        • Product stewardship
        • Safety data sheets
      • Services
        • ACCURA
        • SECCURA
        • Cryobank sample storage
        • CRYOSPEED
        • Gas analysis
        • Preventative maintenance
        • Safety training
        • Total gas management
  • Specialties for you
      • Industries
        • Aerospace
        • Automotive industry
        • Clinical & life science
        • Chemicals production
        • Commercial laboratories
        • Environmental protection
        • Food & beverage
        • Glass industry
        • Lighting industry
        • Manufacturing
        • Mining & metallurgy
        • Petrochemical processing
        • Pharmaceutical & biotechnology
        • Power generation
        • Research institutes & universities
      • Applications
        • Air quality monitoring
        • Biological growth control
        • Breath alcohol testing
        • Calorimetric measurement
        • Emission testing for on-road and off-road vehicles and machinery
        • Commercial diving
        • Confined space monitoring
        • Emission trading
        • Explosimetry
        • Food packaging
        • Heat treatment of metals
        • Laser cutting & welding
        • Leak testing
        • Natural gas trading
        • Olfactometry
        • Process control
        • Soil and water measurement
        • Solvent & VOC monitoring
        • Stack emission monitoring
        • Windows insulation
        • Work place monitoring
      • News & events
        • Journal articles
      • PDF downloads
      • Videos
        • Certification of analysis
        • Safety
        • Laboratoratory use
        • Regulators purging
        • Regulators for small cylinders
        • Specialty equipment
        • Euro 6
        • Gas chromatography
        • Specialty gases cylinders
      • Exclusively HiQ
        • HiQ cylinders
        • HiQ gases
        • HiQ equipment
        • HiQ services
        • SPECTRA products
  • Careers
      • Jobs @ Linde
  •  
  • Linde Worldwide
  • The Linde Group
  • Glossary
  • Contact us
  • Specialty gases
  • Gas mixtures
  • Instrumentation gas table
  • Euro 6 gases & gas mixtures
  • Industrial laser gases
  • Rare gases
  • Zero gases
  • Specialty gases cylinder outlets
  • Portable cylinders
  • Supply modes
  • CAS number listing
  • Material compatibility
  • Physical data
  • Specialty gases
  • Instrumentation gas table

Instrumentation gas table

Linde offers a wide range of high purity carrier, purge and detector gases. Our instrumentation gas finder offers suggestions for the respective instruments. For more detailed purity specifications, please review the HiQ pure gases finder requirements for your application. Please note that purity and gas specifications may differ depending on instrument manufacturer. Contact the HiQ Expert Team if you need precise information about the gas requirements for your analyser.

Instrumentation
Impurity Concern
Carrier (C), Detector (D), Make up (M), Nebuliser (N), Purge (P), Reaction (R) Gases*
Recommendations: RL - Redline, BL - BASELINE, Regulators Generators**    
CHROMATOGRAPHY
Flame Ionization
Detector (FID)
THC C/M: HiQ Helium 5.0 BL C106 series
H2O C/M: HiQ Nitrogen 5.0 BL C106 series HiQ N2 SIROCCO
O2 C/D: HiQ Hydrogen 5.0 BL C106 series HiQ H2 FID
D: HiQ Synthetic Air 5.0 BL C106 series HiQ Zero Air
D: 40% Hydrogen
in Helium
BL C106 series
D: 40% Hydrogen
in Nitrogen
BL C106 series
Thermal
Conductivity
Detector (TCD)
THC C/M: HiQ Helium 5.0 BL C106 series
H2O C/M: HiQ Hydrogen 5.0 BL C106 series HiQ H2 CARRIER
O2 C/M: HiQ Nitrogen 5.0 BL C106 series HiQ N2 SIROCCO
Electron Capture
Detector (ECD)
THC C: HiQ Helium 5.5 ECD RL C200 series
H2O C: HiQ Hydrogen 5.0 Zero RL C200 series HiQ H2 CARRIER
O2 C/M: HiQ Nitrogen 5.0 ECD RL C200 series HiQ N2 SIROCCO
Halocarbons C/M: 5% Methane
in Argon ECD
RL C200 series
C/M: 10% Methane
in Argon ECD
RL C200 series
Flame Photometric
Detector (FPD)
Sulphur or
phosphorous
components
C: HiQ Argon 5.0 Zero BL C106 series  
  (H2S, SO2,THT,
Sulphides) CO2
C: HiQ Helium 5.0 Zero BL C106 series  
    C/M: HiQ Nitrogen 5.0 Zero BL C106 series HiQ N2 SIROCCO
    C/D: HiQ Hydrogen 5.0 Zero BL C106 series HiQ H2 CARRIER
    D: HiQ Synthetic Air 5.0 BL C106 series HiQ Ultra Zero Air
Nitrogen
Phosphorus
Detector (NPD)
NH3 C/M: HiQ Helium 5.0 BL C106 series  
  Amines C/M: HiQ Nitrogen 5.0 BL C106 series HiQ N2 SIROCCO
    D: HiQ Hydrogen 5.0 BL C106 series HiQ H2 CARRIER
    D: HiQ Synthetic Air 5.0 BL C106 series HiQ Ultra Zero Air
Photo Ionization
Detector (PID)
THC C: HiQ Helium 5.0 Zero BL C106 series  
  CO2 C: HiQ Nitrogen 5.0 Zero BL C106 series HiQ N2 SIROCCO
Pulse Discharge
Photo Ionization
Detector (PDPID)
  C/P: HiQ Helium 6.0 RL C200 series  
Supercritical Fluid
Chromatography
(SFC)
H2O
Nonvolatile;
Liquide phase
FID&ECD
responsive;
Gas phase;
O2&THC
C: HiQ Carbon dioxide 4.5 SFC BL C106 series  
High Performance
Liquid
Chromatography
(HPLC)
  P:

HiQ Helium 5.0

BL C106 series  
Evaporative Light
Scattering Detector
(ELSD)
  N: HiQ Nitrogen 4.6 BL C106 series HiQ N2 ELSD
Instrumentation
Impurity Concern

 

Carrier (C), Detector (D), Make up (M), Nebuliser (N), Purge (P), Reaction (R) Gases*
     Recommendations: RL - Redline, BL - Basseline, Regulators Generators**
SPECTROMETRY
Gas Chromatography
Mass Spectrometry
(GC-MS)
THC    C: HiQ Helium 5.0 Zero BL C106 series        
  H2O            C: HiQ Hydrogen 5.0 Zero BL C106 series HiQ H2 CARRIER
  O2 C: HiQ Nitrogen 5.0 Zero BL C106 series HiQ N2 SIROCCO
  CO2        
Liquid
Chromatography
Mass Spectrometry
(LC-MS)
THC P:

HiQ Helium 5.0

BL C106 series  
    P: HiQ Nitrogen 5.0 Zero BL C106 series HiQ N2 LCMS
Inductively Coupled
Plasma Spectrophotometer -
Mass Spectrometry
(ICP-MS)
D: HiQ Argon 5.0 BL C106 series  
    R: HiQ Helium 6.0 RL C200 series  
    R: HiQ Ammonia 5.0 RL C200 series  
Fourier Transform
Infrared
Spectroscopy (FTIR)
H2O P: HiQ Nitrogen 5.0 BL C106 series HiQ N2 SIROCCO
  THC P: HiQ Argon 5.0 BL C106 series  
  HC        
Atomic Absorption
Spectrometry (AAS)
H2O D: HiQ Synthetic Air 5.0 BL C106 series HiQ Ultra Zero Air
  H2S D: HiQ Nitrous Oxide 2.5 AAS BL C106 series  
  PH3 D: HiQ Acetylene 2.6 AAS BL C106 series  
Atomic Absorption
Spectrometry
Graphite furance
(GF-AAS)
  D: HiQ Argon 5.0 BL C106 series  
Inductively Coupled
Plasma
Spectrophotometer
(ICP)
  D: HiQ Argon 5.0 BL C106 series  

* The gas recommendations include minimum purity requirement.

**Gas Generators:
The HiQ H2 Air FID station has been designed to feed GC's with Hydrogen and Zero Air at the same time.

Linde offers a wide range of high purity carrier, purge and detector gases. Our instrumentation gas finder offers suggestions for the respective instruments. For more detailed purity specifications, please review the HiQ pure gases finder requirements for your application. Please note that purity and gas specifications may differ depending on instrument manufacturer. Contact the HiQ Expert Team if you need precise information about the gas requirements for your analyser.

Any questions?

Ask our experts!

Contact

    • YouTube Social Media icon
    • Terms of Use
    • Legal Notice
    • Data Protection
  • © The Linde Group 2019

To enhance your user experience and to deliver our online services, this website uses cookies for reasons of functionality, comfort and statistics. By continuing to browse the site, you are agreeing to our use of cookies.
You can find out more on our data protection information.
You must check the "I accept cookies from Linde Sites" box to accept.
More